Sensors
Ann Ultrasonic Sensor is a mechanical vibration sensor; the frequency of the vibration is higher than acoustic waves. Compared with the acoustic wave, the ultrasonic wave has a shorter length, a smaller diffraction and a better directional characteristic. It can be used for the directional communication. Also ultrasound has great penetration skills in liquids, solids, especially opaque solids in the sun, which can be penetrated up to a depth of 10 meters. Ultrasonic Waves encountering impurity or sub-interface can generate reflex, so it can be widely used in industry, national defense, biomedical and so on.Our plant designed a special CNC machine for the aluminum housing and a laser adjustment machine to modulate the resonant frequency of the sensor.

Test methods of ultrasonic sensors:
1. Sound Pressure Level and Center Frequency
2. Receiving Sensitivity and Center Frequency
3. Free Capacitance, Medium Wastage
4. Impedance, Resonant Frequency
5. Echo and Rest. Resonant Time
6. Directivity

Series Specifications  
US = Ultrasonic Sensor
Diameter and frequency P = Pin
W = Wire
SENSORS
Click on product part for data sheet of our SENSORS Close
  US1240 PA >> US1440PA >> US1458WA >> US1640PA >>
Operating temperature -30°C to 85°C -40°C to 85°C -40°C to 85°C -40°C to 85°C
Storage temperature -30°C to 85°C -40°C to 85°C -40°C to 85°C -40°C to 85°C
Contact Pin Pin Pin Pin
Operating Mode Dual mode Dual mode Dual mode Dual mode
Detection area [m] 12 0.3 - 1.5 0.2 - 4
Center frequency [kHz] 40 40 58 40
Capacity [nF] at 1kHz 2 ± 20% 2.2 ± 25% 2 ± 25% 2 ± 20%
Direction [deg] 80 110 x 45
Sensitivity [Vμbar] -75 -75 -90 -75
SPL [dBA] 110 97 100 10
  US1840P-01A >> US1840PA >>
Operating temperature -40°C to 100°C -30°C to 85°C
Storage temperature -40°C to 100°C -30°C to 85°C
Contact Pin Pin
Operating Mode Dual mode Dual mode
Detection area [m] 0.2 - 1.5 0.3 - 5
Center frequency [kHz] 40 40
Capacity [nF] at 1kHz 2 ± 20% 2 ± 20%
Direction [deg]
Sensitivity [Vμbar] -74 -74
SPL [dBA] 100 106
Close